REFURBISHED Certified Patient Ready Philips Trilogy 202 Ventilator
REFURBISHED Certified Patient Ready Philips Trilogy 202 Ventilator
SKU:T202-R
CUSTOM ORDER - SHIPS WITHIN 7 TO 14 BUSINESS DAYSIncluded with Sales:
- One Certified Patient Ready Philips Respironics Trilogy 202 Medical Ventilators with Supporting Documents
- One Power Cord
- Complete Preventive Maintenance Update by our Certified Technicians
- 12 Month Full Coverage Warranty
- Free Shipping to the Lower 48 USA States
The Trilogy 202 is both a volume-control and pressure-control ventilator for invasive and noninvasive ventilation. The versatile breath delivery and setup options free you from burdensome equipment exchanges, providing greater continuity of care for your patients.
Because the Trilogy 202 has the unique ability to compensate for leaks in both pressure and volume control modes, using simpler passive circuits may support significant time and cost savings. With one simple setting change, the Trilogy 202 supports either active or passive exhalation breathing circuits to accommodate changes in circuit preference.
Simplicity and versatility Philips Respironics Trilogy 202 portable ventilator specifications Key advantages
Compact design with long-life internal battery for intra-hospital transport.
Supports active and passive circuits for invasive and noninvasive ventilation.
Innovative leak compensated volume control ventilation.
The Trilogy 202 is both a volume-control and pressure-control ventilator for invasive and noninvasive ventilation
The versatile breath delivery and setup options free you from burdensome equipment exchanges, providing greater continuity of care for your patients.
Trilogy 202 has the unique ability to compensate for leaks in both pressure and volume control modes, using simpler passive circuits may support significant time and cost savings.
With one simple setting change, the Trilogy 202 supports either active or passive exhalation breathing circuits to accommodate changes in circuit preference.
Patient types :
- Pediatric (≥5 kg)
- Adult
Modes:
- Volume Assist control (AC)
- Synchronized intermittent mandatory ventilation (SIMV)
- SIMV with pressure support (SIMV w/PS)
- Control ventilation (CV)
Pressure:
- Pressure control (PC)
- Pressure control-SIMV (PC-SIMV)
- Spontaneous ventilation (S)
- Spontaneous ventilation with timed back-up (S/T)
- Timed ventilation (T)
- Continuous positive airway pressure (CPAP)
- Average volume assured pressure support (AVAPS) with passive circuit type, S, S/T, PC, and T modes only
Synchrony features:
- Auto-Trak sensitivity: Auto-adaptive triggering, cycling, and leak compensation (available in all modes, passive circuit only)
- Adjustable flow triggering 1 – 9 l/min (available in all modes and circuit types)
Circuit types:
- Active exhalation valve with proximal airway pressure (PAP)
- Active exhalation valve with flow sensor Passive exhalation port
Controls:
IPAP 4 – 50 cmH2O
EPAP/PEEP 0 – 25 cmH2O (active valve circuits) 4 – 25 cmH2O (passive leak port circuits)
CPAP 4 – 20 cmH2O (passive leak port circuits)
Pressure support 0 – 30 cmH2O
Tidal volume 50 – 2000 ml
Breath rate 0 – 60 BPM (AC mode) 1 – 60 BPM (all other modes)
Inspiratory time 0.3 – 5.0 s
Rise time 1 – 6 (relative scale)
Ramp start pressure 0 – 25 cmH2O (active circuits) 4 – 25 cmH2O (passive circuits) 4 – 19 cmH2O (CPAP mode)
Ramp time Off, 5 – 45 min
C-Flex Off, 1 – 3 (relative scale)
Flow trigger sensitivity 1 – 9 l/min
Flow cycle sensitivity 10 – 90%
Monitored parameters:
Tidal volume 0 – 2000 ml
Minute ventilation 0 – 99 l/min
Estimated leak rate 0 – 200 l/min
Respiratory rate 0 – 80 BPM
Peak inspiratory flow 0 – 200 l/min
Peak inspiratory pressure 0 – 99 cmH2O
Mean airway pressure 0 – 99 cmH2O
% patient triggered breaths 0 – 100%
I:E ratio 9.9:1 – 1:9.9